IT Cleaning Ltd specialise in the Data Centre Cleaning, Server Room Cleaning, Communication Room Cleaning, Computer Room Cleaning and other IT infrastructure. Cleaning the room and the equipment within the room.
While submicron particle and gaseous contamination resulting from dust and dirt can lead to unexpected shutdowns of mission critical IT equipment, the connection between contamination and hardware failures is often overlooked. Dust contamination, which has been referred to as the undetected disaster and has been shown to causes 70% of breakdowns of equipment within I.T. envir
View More
Protecting IT Equipment from Construction Dust
IT Cleaning Ltd can enclose the IT Equipment or the work area. Then using air scrubbers, we will create a positive or negative pressure, which will ensure dust from the work area, can not migrate into the IT Equipment. By either keeping it out (enclosing IT equipment, positive pressure) or keeping it in the work area (enclosing Work area, negative pressure). We can control temperature within the enclosure to ensure equipment can continue to work whilst the refurbishment is happening.
We will supply a manager to manage control of the contamination. Such as egress into and out of the space,...
View More
IT Cleaning Ltd carry out PC cleaning, computer cleaning, telephone cleaning, printer cleaning and other peripheral items.
IT Cleaning Limited defines a PC as the following.
.Monitor
.Keyboard
.Hard Drive
.Mouse (not remove ball)
.Cables from keyboard and mouse (as far as can access)
Professional PC cleaning as defined above takes approximately 15 minutes per PC.
The price per PC will depend on a number of variables as follows.
ITDecomTiles
IT Cleaning Ltd can supply ITDecom tiles, which actively remove particulate (dust) from feet, wheels and anything else that comes into contact with the surface. Utilising Van De- Waals force the dust is attracted to the surface and then held there.
These tiles are not sticky unlike Tack Mats. They are big enough for a person to take 3 or 4 steps on, do not require any peeling and are unavoidable, agan unlike Tack Mats. ITDecom tiles are made to the same s
View More
A Standard For Cleanliness ISO 14664-1
Less than optimally clean hardware can severely impact data center performance. Submicroscopic particulates can interfere with your valuable equipment’s electronics, leading to hard-to-troubleshoot problems and even data loss.
Dissipating heat is essential to data center operations, which means maintaining a steady airflow through the data center. But this constant airflow can bring
View More
High failure rates were encountered on PCBs and power supplies within data processing equipment in a large data processing centre in North East England. The problem was traced to small metallic particles of zinc being deposited on the PCBs and causing inter-track conduction. The source of the zinc was the galvanised coating on the underside of the raised floor tiles. Examination found that zinc whiskers were present and were being carried in the airflow from the pressurised under floor plenum into the intake vents of the equipment.
What are zinc whiskers?
Zinc whiskers 'grow' from metal surfaces that have been coated with zinc to help protect them from corrosion. Whisker growth appears to be limited to electroplated
View More
IT Cleaning Ltd have contracts to clean for a number of broadcasters in and around London. Dust is a big problem within the broadcast environment as the equipment is always on. Static and other forces then work on the ever-present dust. This dust is very small in the range 0.5 micron to 5 micron. The main problems experiences would be, mechanical effects: These effects include obstruction of cooling airflow, interference with moving parts, abrasion, optical interference, interconnect interference, or deformation of surfaces (e.g., magnetic media) and other similar effects.
IT Cleaning Ltd clean the following areas:
Main Control Rooms (MCR). MCR cleaning is done on a 3 monthly cycle removing dust from the room and the equipment.
 
View More
IT Cleaning Ltd are often asked to carry out server cleaning internally. This is need when a server is subjected to large amounts of dust, often from construction activities like drilling, whilst running.
IT Cleaning Ltd will remove the server from the rack. Then ensuring we are protected against static we will strip the server to its component parts. Remove fans, airways, disks and other removable items. We will then clean the server using HEPA filtered vacuums and specialist tools. Once we have completed the clean we will reassemble the server and put it back in its rack.